Product Detailed
Related Categories:Power Distribution Equipment
Related Product Searches:Disconnect Switch High Voltage,High Quality,Disconnect Switch, fuse disconnecting switch,GW9-15/630
1. Reliable operation.
2. Supplier for China State Grid.
3. IEC and GB (China standard) standard
4. 15kV,24kV,36kV.
Related Product Searches:Disconnect Switch High Voltage,High Quality,Disconnect Switch, fuse disconnecting switch,GW9-15/630
Introduction
GW 9 Series Outdoor H.V. Isolating switch used for rated voltage 10-38kV power system. The isolation section available in porcelain insulator or polymer insulator.
Normal conditions of use1,The altitude does not exceed 1000m.2,The ambient air temperature:Maximum+40°C;Minimum:General Area-30°C ,paramos-40°C .3,The wind pressure does not exceed 700Pa(corresponding to 34m/s wind speed).4,The earthquake intensity does not exceed 8 degrees.5,The working situation without frequent violent vibration.
Installation Note
The installation site of ordinary isolator should be away from gas,smoke chemical deposition,salt,spray fog,dust and other expiosive and corrosive materials that affect seriously insulation and conuction capability of the isolator.Pollutionproof type isolator is apples to severe filthy conduction area.however.It shouldn' be any explosive matters and matters causing fireMain technique data
Model | GW9-15/400 | GW9-15/630 | GW9-15/900 | GW9-24/400 | GW9-24/630 | GW9-24/900 | GW9-36/400 | GW9-36/630 | GW9-36/900 |
Rated Voltage(kV) | 15 | 15 | 15 | 24 | 24 | 24 | 36 | 36 | 36 |
Rated Current (A) | 400 | 630 | 900 | 400 | 630 | 900 | 400 | 630 | 900 |
Momentary Current (A) | 40000 | 40000 | 40000 | 40000 | 40000 | 40000 | 40000 | 40000 | 40000 |
BIL kV | 125 | 125 | 125 | 150 | 150 | 150 | 200 | 200 | 200 |
Short Time Withstand | 25000 | 25000 | 25000 | 25000 | 25000 | 25000 | 25000 | 25000 |
Disconnect Switch High Voltage
Verified Information This information is Verified by Bureau Veritas and validity period is 2012/08/31 --- 2013/08/31 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Surge Arrester, Drop-out Fuse Cutout, Insulator, Disconnect Switch, Metal-Oxide Varistor | Surge Arrester: 350,000 pcs per year, Drop-out Fuse Cutout: 230,000 pcs per year, Insulator: 350,000 pcs per year,Disconnect Switch: 60,000 pcs per year, Metal-Oxide Varistor: 550,000 pcs per year | confidential |
North America | confidential | 4.0 |
South America | confidential | 10.0 |
Eastern Europe | confidential | 1.0 |
Southeast Asia | confidential | 3.0 |
Africa | confidential | 8.0 |
Oceania | confidential | 1.0 |
Mid East | confidential | 10.0 |
Eastern Asia | confidential | 10.0 |
Western Europe | confidential | 2.0 |
Central America | confidential | 1.0 |
Northern Europe | confidential | 1.0 |
Southern Europe | confidential | 1.0 |
South Asia | confidential | 1.0 |
Domestic Market | confidential | 47.0 |
Rubber mixing machine | SXK360*900 | 3 | 10.0 | Acceptable |
Vulcanizing machine | QLB150T | 13 | 1.0 | Acceptable |
Varistor drying oven | SD-SG13 | 4 | 3.0 | Acceptable |
Crimping machine | YJ-890E | 3 | 5.0 | Acceptable |
Granulating machine | No information | 1 | 10.0 | Acceptable |
Punching machine | J23-35 | 10 | 10.0 | Acceptable |
Torque test machine | YJN-WN-2010 | 1 | 6.0 | Acceptable |
High-voltage test system | YDTCW-60/300-I | 1 | 6.0 | Acceptable |
Partial discharge detector | JF-2001 | 1 | 6.0 | Acceptable |
Aging test instrument | 401B | 1 | 6.0 | Acceptable |
Surge arrester tester | MOA-200 | 3 | 6.0 | Acceptable |
Impulse current generator | CJL-II | 3 | 6.0 | Acceptable |
Inspection Report | Quality Inspection and Test Center for Equipment of Electric Power | Metal-oxide surge arrester polymeric-housed without gaps for a.c. system & YH5W-36/108, YH5W-24/72, YH5W-12/36 | 2007/09/08 | |
Type Tests Report | KEMA | Metal-oxide surge arrester without gaps & Series YH 10W-12-36KV | 2006/12/12 |